Abstract
A new biotribo-acoustic testing system for orthopaedic biomaterials was developed and validated. Experiments on the biotribo-acoustic testing methodology, especially for ceramic-on-ceramic biomaterial wear couples, were carried out via this testing system. Deionized water and biomimetic synovial fluids (BSF) were chosen as two lubricants in the tests. The results showed that the coefficient of friction agreed well with the sound pressure and sound power. The correlation between the biotribological and acoustic data was established in vitro. The difference in wear mechanisms was distinguished. A potential solution can be provided to investigate the biotribological and acoustic properties of orthopaedic biomaterials in vitro.
| Original language | English |
|---|---|
| Pages (from-to) | 1-6 |
| Number of pages | 6 |
| Journal | Tribology International |
| Volume | 71 |
| DOIs | |
| State | Published - 2014 |