Skip to main navigation Skip to search Skip to main content

450 nm半导体蓝激光对子宫内膜组织 汽化切割效应的离体动物实验研究

Translated title of the contribution: Effects of 450 nm semiconductor blue laser on the vaporization and incision of endometrial tissue ex vivo
  • Guo Xiong Liu
  • , Li Hong Chen
  • , Fen Li
  • , Yan Xue
  • , Da Li Jiang
  • , Xiao Feng Xu
  • , Rui Fang An
  • , Xin Yang Wang
  • , Xi Min Qiao
  • , Da Lin He
  • , Kai Jie Wu
  • Department of Urology
  • The First Affiliated Hospital of Xi’an Jiaotong University
  • Shaanxi Province
  • Department of Obstetrics and Gynecology
  • Shaanxi Provincial People's Hospital
  • Department of Obstetrics and Gynecology
  • Department of Urology

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

Objective The 450 nm semiconductor blue laser surgical system was used to perform vaporization and incision of fresh endometrial tissue ex vivo under different conditions and endoscopic simulated surgery experiments to initially evaluate the safety, efficacy and feasibility of blue laser in gynecological surgical applications. Method 8 fresh uteri were taken from each of the pregnant and non-pregnant swines. Vaporization and incision of endometiral tissue was performed using 450 nm core fiber. The moving speed of the stepper (V) is 1.0 mm/s, 2.0 mm/s, the distance (D) of the fiber head is adjusted to 0.5~1.0mm from the tissue, and the power of the laser is 5~30 W. Photographs after vaporization were recorded, and specimens were put into 4% paraformaldehyde for HE test. Vernier caliper was used to measure the thickness of the coagulation, width and depth of the vaporization. 8 postpartum uteri were used, and in contrast with plasma electrocut equipment, vitro simulated operation was done under the endoscope assisted. The specimens of postoperation was done HE staining. Result Blue laser acts on the endometrial tissue at different power (5~25 W), and as the laser power increases, the vaporization depth and vaporization width of the tissue gradually increases. A comparison of vaporization cutting experiments using a bipolar plasma electrosurgery device with the blue laser under endoscopy showed that the cut surface of blue laser was flatter. There was no obvious carbonization layer after the vaporization of the blue laser. The range of thermal damage for the blue laser was limited and controllable, and the thickness of the coagula-tion, the depth and width of the vaporization were stable. Compared to plasma electrocut equipment, the blue laser produces a relatively small range of thermal damage. Conclusion We concluded that the blue laser is a safe, effective and feasible surgical instrument for the treatment of the endometrial lesions. And the blue laser should be expected to become a new apparatus for physician of the department of gynaecology.

Translated title of the contributionEffects of 450 nm semiconductor blue laser on the vaporization and incision of endometrial tissue ex vivo
Original languageChinese (Traditional)
Pages (from-to)2-7
Number of pages6
JournalYixue Xinzhi Zazhi
Volume33
Issue number1
DOIs
StatePublished - 25 Mar 2023
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Effects of 450 nm semiconductor blue laser on the vaporization and incision of endometrial tissue ex vivo'. Together they form a unique fingerprint.

Cite this