Skip to main navigation Skip to search Skip to main content

负载因素对 10 kV 三相油浸式配电变压器振动特性影响的仿真研究

Translated title of the contribution: Simulation Research on Influence of Load Factors on Vibration Characteristics of 10 kV Three Phase Oil Immersed Distribution Transformer
  • Xiaowen Wu
  • , Zhuangzhuang Zhang
  • , Lingyu Zhu
  • , Fan Zhang
  • , Hao Cao
  • , Meisheng Yi
  • State Grid Corporation of China
  • Xi'an Jiaotong University
  • TBEA Hengyang Transformer Co.,Ltd.

Research output: Contribution to journal › Article › peer-review

13 Scopus citations

Abstract

For studying the influence of load factors on vibration characteristics of three-phase oil immersed distribution transformer,a kind of simulation calculation method of vibration of transformer proper based on Comsol Multiphysics finite element software is proposed in this paper. Through the harmonic response analysis method,the vibration of the winding under load and the magnetostrictive vibration of the iron core under no-load are calculated respectively,and then both of them are coupled to obtain the vibration of transformer proper. In this paper,the influence of load unbalance,load capacity and power factor angle on the vibration characteristics of transformer is studied. The study results show that when the load unbalance of phase B is compared to that of the other two phases,the amplitude of maximum acceleration of oil tank surface is smaller. The surface vibration of the transformer oil tank is related to the load capacity,and the vibration of the oil tank under light load is mainly affected by the iron core vibration. With the increase of load capacity,the surface vibration of the oil tank increases gradually. While,with the increase of power factors,the maximum acceleration of the front surface of the oil tank increases and the that on the side surface decreases . The vibration concentration area of the oil tank is transferred from the side surface to the front surface. The study results in this paper have reference significance for the arrangement of measuring points and vibration control of transformer.

Translated title of the contributionSimulation Research on Influence of Load Factors on Vibration Characteristics of 10 kV Three Phase Oil Immersed Distribution Transformer
Original languageChinese (Traditional)
Pages (from-to)106-115
Number of pages10
JournalGaoya Dianqi/High Voltage Apparatus
Volume58
Issue number10
DOIs
StatePublished - 16 Oct 2022

Fingerprint

Dive into the research topics of 'Simulation Research on Influence of Load Factors on Vibration Characteristics of 10 kV Three Phase Oil Immersed Distribution Transformer'. Together they form a unique fingerprint.

Cite this