田湾核电站3、4号机组主给水泵2倍频振动原因分析与处理

Translated title of the contribution: Causal Analysis and Resolution of Main Feedwater Pump Frequency-Doubled Vibration of Tianwan NPP Units 3 and 4
  • Di Zhao
  • , Xiaomeng Chen
  • , Xiufeng Wang
  • , Zhongzhi Sun
  • , Zhengping Zhou
  • , Zhijun Zhou
  • , Guanghui Hu

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

The main feedwater pump frequency-doubled vibration occurred in Tianwan NPP units 3 and 4 in the process of commissioning. The frequency-doubled is approximately equal to the three times frequency of the pump structure according to the result of modal test. The three times frequency of the pump structure is increased by reinforcing the pedestal of the main feedwater pump. According to the test result, the vibration of the bearing pedestal is reduced obviously. The reinforcement results in good effect.