Abstract
Dynamic desorption of water molecule from the capillary wick comprising highly porous nickel-powder sintered and coated on the inner surfaces of loop heat pipe (LHP),an advanced thermal control device in spacecraft and submarine,was empirically approximated,mathematically formulated with dynamic/neural-network/grey-forecasting models based on the experimental data measured and/or reported in literature,theoretically analyzed and numerically simulated to predict the service lifetime of LHP. The simulated results show that when it comes to time-evolution of water desorption rate/quantity,a descending order can be listed:2nd-order dynamic model (124.90×10-6 and 150 d) > neural-network model (109.60×10-6 and 75 d) > 1st-order dynamic model (81.49×10-6 and 30 d) > grey-forecasting model (59.06×10-6 and 24 d).We suggest that neural-network model may best describe the dynamic water-desorption characteristics from capillary wick in LHP.
| Translated title of the contribution | Dynamic Water Desorption from Capillary Wick in Loop Heat Pipe:A Simulation and Analytical Study |
|---|---|
| Original language | Chinese (Traditional) |
| Pages (from-to) | 505-509 |
| Number of pages | 5 |
| Journal | Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology |
| Volume | 40 |
| Issue number | 6 |
| DOIs | |
| State | Published - 1 Jun 2020 |
Fingerprint
Dive into the research topics of 'Dynamic Water Desorption from Capillary Wick in Loop Heat Pipe:A Simulation and Analytical Study'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver