Skip to main navigation Skip to search Skip to main content

燃煤发电机组低负荷温压同滑性能优化研究

Translated title of the contribution: Research on Performance Optimization of Coal-fired Power Generation Units Under Simultaneous Temperature and Pressure Variations at Low-load Conditions
  • Wencong Yi
  • , Zefeng Liu
  • , Pengjiang Xu
  • , Tingshan Ma
  • , Chaoyang Wang
  • , Ming Liu
  • , Junjie Yan
  • Xi'an Jiaotong University
  • Thermal Power Research Institute

Research output: Contribution to journal › Article › peer-review

Abstract

To reduce power consumption rate of coal-fired units during deep peak shaving operation, a mechanism model suitable for low-load conditions was established based on a 660 MW unit as the research object. The reliability of the model was verified using actual operation data. Based on thermodynamic theory, the energy consumption distribution characteristics of the unit under low-load conditions were analyzed, and the strategy was proposed to improve the relative internal efficiency of the steam turbine under low-load conditions by adjusting the working fluid flow rate. Results show that compared with the rated condition, the theoretical cycle efficiency decreases by 4.67% under the low-load condition, the boiler efficiency decreases by 0.43%, and the relative internal efficiency of the steam turbine decreases by 8.96%. After comparing before and after flow adjustment, it is found that the unit operates with simultaneous temperature and pressure changes under low-load conditions, which has higher thermal economy than the original sliding pressure operation. Taking 198 MW as an example, after adjusting the flow rate, the relative internal efficiency of the steam turbine increases by 1.57%, and the power consumption rate decreases by 1.137 g/(kW·h). Under the operating conditions of 130, 230 and 340 MW for the unit, after adjusting the flow rate, the power consumption rates are reduced by 1.147, 0.067 and 0.313 g/(kW·h), respectively. The study can provide certain reference for optimizing the flow rate operation of coal-fired units during deep peak shaving conditions.

Translated title of the contributionResearch on Performance Optimization of Coal-fired Power Generation Units Under Simultaneous Temperature and Pressure Variations at Low-load Conditions
Original languageChinese (Traditional)
Pages (from-to)121-131
Number of pages11
JournalDongli Gongcheng Xuebao/Journal of Chinese Society of Power Engineering
Volume46
Issue number7
DOIs
StatePublished - 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Fingerprint

Dive into the research topics of 'Research on Performance Optimization of Coal-fired Power Generation Units Under Simultaneous Temperature and Pressure Variations at Low-load Conditions'. Together they form a unique fingerprint.

Cite this