Abstract
With the trend of processing sulfur-containing crude oil, the circulation of desulfurization solvent is increasing in refineries, which raises the energy consumption for solvent regeneration dramatically. In this paper, Aspen HYSYS is used to simulate a group of desulfurization units, and the minimum desulfurization solvent circulation of each unit is obtained. On this basis, two retrofitting methods, cascaded operation and cascaded-parallel operation, are put forward and used to retrofit the desulfurization system. The results show that the desulfurization solvent circulation can be reduced by 8.82% and 10.01% through the two methods, respectively, and have achieved good economic benefits. Finally, the advantages and disadvantages of the two methods are analyzed and discussed, which provides directions and suggestions for the optimization of refinery desulfurization system.
| Translated title of the contribution | Simulation and retrofit of desulfurization system in refinery |
|---|---|
| Original language | Chinese (Traditional) |
| Pages (from-to) | 1473-1479 |
| Number of pages | 7 |
| Journal | Huagong Xuebao/Journal of Chemical Industry and Engineering (China) |
| Volume | 72 |
| Issue number | 3 |
| DOIs | |
| State | Published - Mar 2021 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Fingerprint
Dive into the research topics of 'Simulation and retrofit of desulfurization system in refinery'. Together they form a unique fingerprint.Cite this