T1 - 某 燃 煤 电 厂 新 型 脱 硫 废 水 处 理 系 统 的 调 试 与 分 析
AU - Liu, Guidong
AU - Hu, Yangyang
AU - Wang, Jing
AU - Chen, Yang
AU - Wang, Zhiyong
AU - Dang, Yulu
AU - Xu, Hao
N1 - Publisher Copyright:
© 2025 Editorial Office of Industrial Water Treatment, CNOOC Tianjin Chemical Research and Design Institute Co., Ltd. All rights reserved.
PY - 2025/1
Y1 - 2025/1
N2 - In a desulfurization wastewater renovation project of a coal-fired power plant in Shandong Province, the original triple-tank process was replaced by integrated high efficiency clarification process to treat the desulfuriza⁃ tion wastewater, with suspended solids of 13 650 mg/L, CODCr of 350 mg/L and heavy metal ion concentration ex⁃ ceeding the standard. The basic chemical dosage could be determined by laboratory test. By on-site equipment joint adjustment, the operating parameters could be optimized and equipment damage rate could be reduced. After 168 h commissioning and running, the new process of desulfurization wastewater system was stable and effective. The efflu⁃ ent SS was 1.5 mg/L, CODCr was 132.2 mg/L, total lead, total cadmium, total mercury, total chromium, and total zinc were 0.14, 0.01, 0.01, 1.04, and 1.24 mg/L, respectively. The effluent quality could meet the relevant indicators of the Discharge Standard of Wastewater from Limestone-Gypsum Flue Gas Desulfurization System in Fossil Fuel Power Plants (DL/T 997-2020). Compared with the original triple-tank process in power plants, the integrated high-efficiency clarification process not only significantly improved water quality, but also reduced annual operating costs from over 1 million yuan to over 0.5 million yuan, with significant economic effects.
AB - In a desulfurization wastewater renovation project of a coal-fired power plant in Shandong Province, the original triple-tank process was replaced by integrated high efficiency clarification process to treat the desulfuriza⁃ tion wastewater, with suspended solids of 13 650 mg/L, CODCr of 350 mg/L and heavy metal ion concentration ex⁃ ceeding the standard. The basic chemical dosage could be determined by laboratory test. By on-site equipment joint adjustment, the operating parameters could be optimized and equipment damage rate could be reduced. After 168 h commissioning and running, the new process of desulfurization wastewater system was stable and effective. The efflu⁃ ent SS was 1.5 mg/L, CODCr was 132.2 mg/L, total lead, total cadmium, total mercury, total chromium, and total zinc were 0.14, 0.01, 0.01, 1.04, and 1.24 mg/L, respectively. The effluent quality could meet the relevant indicators of the Discharge Standard of Wastewater from Limestone-Gypsum Flue Gas Desulfurization System in Fossil Fuel Power Plants (DL/T 997-2020). Compared with the original triple-tank process in power plants, the integrated high-efficiency clarification process not only significantly improved water quality, but also reduced annual operating costs from over 1 million yuan to over 0.5 million yuan, with significant economic effects.
KW - coal-fired power plant
KW - commissioning
KW - desulfurization wastewater
KW - integrated high efficiency clarification equipment
UR - https://www.scopus.com/pages/publications/85216331866
U2 - 10.19965/j.cnki.iwt.2024-0313
DO - 10.19965/j.cnki.iwt.2024-0313
M3 - 文章
AN - SCOPUS:85216331866
SN - 1005-829X
VL - 45
SP - 179
EP - 185