Skip to main navigation Skip to search Skip to main content

基于降阶模型的反应堆压力容器保温结构传热性能逆优化设计

Translated title of the contribution: Inverse optimization design of heat transfer performance for the reactor pressure vessel insulation structure based on reduced-order model
  • Jie Zhao
  • , Yanjun Dai
  • , Yungang Wang
  • , Zhenyuan Guo
  • , Fan Bai
  • School of Energy and Power Engineering

Research output: Contribution to journal › Article › peer-review

Abstract

[Background] Thermal leakage in reactor pressure vessel (RPV) insulation structure poses safety risks, and traditional trial-and-error parameter optimization methods are inefficient for handling complex variables. [Purpose] This study aims to develop a proper orthogonal decomposition (POD)-based inverse design methodology to enhance the thermal performance of RPV insulation structure. [Methods] Firstly, three design variables (air supply temperature, RPV outer wall temperature, and installation gap) and their corresponding level numbers were systematically determined, and three optimization objectives were defined as average heat flux (qave), average temperature (Tave) on the RPV insulation's outer wall, and maximum local temperature (Tmax) of the concrete. Then, a comprehensive dataset comprising 24 computational fluid dynamics (CFD) simulations was generated through full factorial design method, with these computational results employed as POD snapshots. Finally, the validated POD method was employed to reconstruct 275 working condition cases, and a dimensionless comprehensive score (FPOD) on a percentage scale was established to evaluate the overall heat transfer performance based on the three optimization objectives. [Results] Calculation results show the POD reconstruction achieved high fidelity is achieved by the POD reconstruction, with an average determination coefficient (R2) exceeding 0.95 and mean relative deviation (MRD) below 2.87%, while reducing CPU time is reduced by 99% compared to CFD. The optimal variable combination (2 mm-16 ℃-309.5 ℃) yieldeds a comprehensive score (FPOD) of 97.4, improving overall heat transfer performance by 59.2% over the original design. [Conclusions] Results of this study demonstrate that the POD-based inverse design methodology provides an efficient and accurate approach for RPV insulation structure optimization. The optimal parameter combination achieves significant improvements in thermal performance, with qave reduced to 84.89 W·m−2, Tave to 35.21 ℃, and Tmaxto 72.86 ℃, which significantly enhances the safety and operational efficiency of RPV insulation structure.

Translated title of the contributionInverse optimization design of heat transfer performance for the reactor pressure vessel insulation structure based on reduced-order model
Original languageChinese (Traditional)
Article number010608
JournalHe Jishu/Nuclear Techniques
Volume49
Issue number1
DOIs
StatePublished - Jan 2026
Externally publishedYes

Fingerprint

Dive into the research topics of 'Inverse optimization design of heat transfer performance for the reactor pressure vessel insulation structure based on reduced-order model'. Together they form a unique fingerprint.

Cite this