Skip to main navigation Skip to search Skip to main content

基于反应堆-斯特林-储能耦合的发电系统特性研究

Translated title of the contribution: Characteristic analysis of a reactor-Stirling-energy storage coupled power generation system
  • Xi'an Jiaotong University

Research output: Contribution to journal › Article › peer-review

Abstract

[Background] To meet the demands of future deep-space exploration and long-duration on-orbit missions for high-power and high-reliability space power supplies, space nuclear reactor power systems have attracted significant attention due to their high power density and superior stability. [Purpose] This study aims to develop a system-level simulation platform for a reactor-Stirling-energy storage coupled power generation system and to analyze its steady-state startup, transient power generation, and DC bus voltage control characteristics. [Methods] First of all, based on MATLAB/Simulink, a system-level model incorporating a nuclear heat source, high-temperature heat pipe heat transfer, Stirling thermoelectric conversion, and a simplified energy storage system was established. Then, a point reactor neutron kinetics model, a high-temperature heat pipe heat transfer model, a free-piston Stirling engine model, and a simplified energy storage model, were integrated into an overall model, enabling full-process simulation from steady-state startup to transient power generation initiated from a steady thermal source. Subsequently, load step simulations were conducted to evaluate the DC bus voltage control performance, and the steady-state startup characteristics of the model were analyzed. Finally, model validation was performed on the basis of the abovementioned system using published literature and experimental data. [Results] Validation results show that the relative error of the heat transfer model compared with published literature is less than 1%, and the key peak-to-peak error of the Stirling engine model compared with experimental data is 4.5%, indicating good agreement. Simulation results indicate that the voltage fluctuation is limited to within 1.5% under steady operation, and the voltage remains stable after load step changes with fluctuations controlled within 5%. When an identical resistive load is connected, the output power doubles, further verifying the effectiveness and validity of the proposed model. [Conclusions] The operating behaviors of all subsystems and system-level coupled response are accurately captured using proposed methods of this study, providing a useful reference for system-level modeling and optimization analysis of reactor-Stirling-energy storage-load coupled power generation systems.

Translated title of the contributionCharacteristic analysis of a reactor-Stirling-energy storage coupled power generation system
Original languageChinese (Traditional)
Article number071108
JournalHe Jishu/Nuclear Techniques
Volume49
Issue number7
DOIs
StatePublished - 15 Jul 2026

Fingerprint

Dive into the research topics of 'Characteristic analysis of a reactor-Stirling-energy storage coupled power generation system'. Together they form a unique fingerprint.

Cite this