Skip to main navigation Skip to search Skip to main content

回风口位置对文物保存环境置换通风调控性能的影响

Translated title of the contribution: Influence of Return-Air Outlet Position on Artifacts’ Preservation Environment with Displacement Ventilation System
  • Xi'an Jiaotong University

Research output: Contribution to journal › Article › peer-review

1 Scopus citations

Abstract

To solve the problems of high energy consumption and large temperature gradient in the local environment control of relics preservation in heritage museum with displacement ventilation (DV) system, an improved DV system, which can reduce the air entrainment from the unconditioned area by laying return-air inlet downwards at the preservation area, was developed. Based on current experimental museum exhibition hall, an experimental setup of the proposed DV system was built. Thus, experiments on natural ventilation system and three DV systems with the heights of return air of 0.4, 0.9 and 1.6 m were performed, and the distributions of temperature and humidity as well as the energy consumption of the system in all test cases were compared and analyzed. The experimental results showed that the DV system could effectively improve the stability of the preservation environment. The fluctuations in temperature and relative humidity were decreased by 50% and 88%, respectively, at a height of 0.2 m from the pit bottom, compared with that of natural ventilation system. Consequently, two thermal stratifications, i.e., 0.2-0.7 m and 1.5-1.7 m were formed in the vertical direction of the preservation area. With the lowering of the height of return air, the DV system enhanced the control over the environmental parameters in the preservation area, and the height of thermal stratification and effective control height were low. Since the downward layout of return-air inlet was set, the load of air-conditioning was decreased by 57.2% averagely compared with the original design. In addition, when the height of return-air inlet decreased from 1.6 m to 0.4 m, the load of air-conditioning per unit area was further decreased by 22.7 W/m2. These results could be used as reference for the design of displacement ventilation control systems.

Translated title of the contributionInfluence of Return-Air Outlet Position on Artifacts’ Preservation Environment with Displacement Ventilation System
Original languageChinese (Traditional)
Pages (from-to)115-122
Number of pages8
JournalHsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
Volume53
Issue number5
DOIs
StatePublished - 1 May 2019