三塔合一间接空冷系统结构参数对 夏季运行特性的影响研究

Translated title of the contribution: Influence of Structural Parameters on the Summer Operational Characteristics of a Three-Tower-in-One Indirect Air-Cooling System
  • Yanqing Meng
  • , Qiangqiang Zhao
  • , Ye Fan
  • , Min Zhu
  • , Dawei Jia
  • , Hancheng Huang
  • , Xiannan Du
  • , Li Han
  • , Jianjun Shi
  • , Yang Zou
  • , Jinwen Shi
  • China National Coal Yili Energy Development Co.,Ltd.
  • Xi'an Jiaotong University
  • National Key Laboratory of High-Efficiency Flexible Coal Power Generation and Carbon Capture Utilization and Storage
  • Ltd.

Research output: Contribution to journal › Article › peer-review

Abstract

To elucidate how the structural parameters of the three-tower-in-one indirect air-cooling system influence its operational characteristics in summer,a coupled calculation model for the system was established under the turbine rated load condition in summer,using commercial simulation software and Internet communication protocols.The accuracy of the system’s simulation model was verified,and the impacts of key structural parameters— including tower height,air inlet diameter, flue gas exhaust height,and chimney diameter— on the system’s operational performance were quantitatively analyzed.The results demonstrate that,as the tower height and air inlet diameter increase,the unit back pressure significantly drops.Specifically,as the tower height increases from 1 90 m to 206 m,the unit back pressure is reduced by 0.73 kPa;as the air inlet diameter increases from 1 2 6 m to 1 38 m,the unit back pressure decreases by 2.04 kPa.The influence of flue gas exhaust height on the unit back pressure was found to be minimal,so much so that it is negligible in engineering practice.When the chimney diameter is increased from 6.5 m to 1 0.5 m, the unit back pressure increases by 0.3 7 kPa.The increase in back pressure gradually levels off as chimney diameter grows,indicating a diminishing impact of chimney area on unit back pressure. Considering both investment costs and operational benefits,it is recommended that the tower height and air inlet diameter should be moderately increased,while the chimney diameter should be slightly decreased.These findings provide a theoretical basis for the structural optimization and improved unit economics of three-tower-in-one indirect air-cooling systems.

Translated title of the contributionInfluence of Structural Parameters on the Summer Operational Characteristics of a Three-Tower-in-One Indirect Air-Cooling System
Original languageChinese (Traditional)
Pages (from-to)46-56
Number of pages11
JournalHsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University
Volume60
Issue number7
DOIs
StatePublished - Jul 2026

Fingerprint

Dive into the research topics of 'Influence of Structural Parameters on the Summer Operational Characteristics of a Three-Tower-in-One Indirect Air-Cooling System'. Together they form a unique fingerprint.

Cite this